Cold radiators, no hot water and a pressure needle sitting in the red. It’s one of the most common winter callouts we get across Bognor Regis and West Sussex, and a lot of the time you can sort it yourself in about five minutes. This guide shows you how to repressurise a boiler safely, whichever type of filling system yours has, and how to tell when topping up isn’t the real fix.

The short answer: switch the boiler off and let it cool, find the filling loop or filling key, let mains water in slowly until the gauge reads between 1 and 1.5 bar, close everything off, then switch the boiler back on and reset it if it asks you to.

What pressure should your boiler be?

Most combi and system boilers run on a sealed heating circuit, and that circuit needs a certain amount of water pressure to move hot water round your radiators. British Gas puts the ideal reading at between 1 and 1.5 bar, and anything under 1 bar usually means it’s time to top up. Vaillant gives the same 1 to 1.5 bar range but points out that the exact figure depends on your model, so it’s worth a quick look at your user manual.

You’ll find the reading on a dial gauge on the front or underside of the boiler, or as a number on the digital display on newer models. Check it with the heating off and the system cold. Pressure naturally creeps up a little when the water heats and expands, so a reading taken while the radiators are hot can make low pressure look fine.

Signs your pressure has dropped too far include:

Work out which filling system you have

This is where most guides skip ahead. There are three common ways to let water into a sealed system, and the steps are different for each. Have a look underneath your boiler (some have a panel that drops down or pulls off) and see which of these you’ve got.

External filling loop

A flexible, braided silver hose with a valve at each end, connecting the cold mains pipe to the heating pipework. Sometimes the hose is left attached; often it’s been taken off and stored nearby, with blanking caps on the two connection points. On system and regular boilers the loop can be on the pipework near the hot water cylinder rather than under the boiler itself.

Keyed internal filling loop

Common on Worcester Bosch combis. There’s no hose, just a small removable key. Worcester Bosch says the key is usually kept on a flap underneath the boiler and fits into a black port at the front right.

Keyless filling link

Also found on many Worcester Bosch boilers. You’ll spot a blue lever at the bottom of the boiler, and that lever is all you need.

If you can’t find any of these, don’t start opening covers. Check the manual or give us a call and we’ll tell you what you’ve got.

How to repressurise a boiler with an external filling loop

  1. Switch the boiler off and let the system cool. Working on a cold system gives you an accurate gauge reading.
  2. If the hose isn’t connected, remove the blanking caps and screw each end on firmly by hand. Have a towel ready for drips.
  3. Open the first valve. On many loops this is a small valve that you turn with a flat screwdriver until the slot lines up with the pipe.
  4. Slowly open the second valve. You’ll hear water flowing into the system and see the gauge needle start to rise.
  5. Watch the gauge closely and close the valve as soon as it reads between 1 and 1.5 bar.
  6. Close both valves fully, one after the other.
  7. Switch the boiler back on and press reset if the display asks for it.
  8. Disconnect the hose, catch the water that drips out, refit the blanking caps and store the hose somewhere you’ll find it next time.

Vaillant’s guide suggests closing the handle valve first and the isolation valve second. Either way, go slowly. Pressure rises quickly once the water starts flowing, and it’s much easier to add a little more than to take some out.

Repressurising a boiler with a keyed internal filling loop

  1. Switch the boiler off and let it cool.
  2. Find the filling key, usually clipped behind a flap on the underside of the boiler.
  3. Line up the arrow on the key with the open padlock symbol and push it into the port.
  4. Turn the key and watch the gauge rise. Worcester Bosch advises stopping at just over 1 bar.
  5. Turn the key back to the open padlock and pull it out. A few drips are normal.
  6. Switch the boiler on, reset it if needed, and put the key back where it lives.

Repressurising a boiler with a keyless filling link

This is the easiest of the three. With the boiler off and cool, pull the blue lever down and hold it while you watch the gauge. Let go once the pressure passes 1 bar, then switch the boiler back on. There’s no hose or key to remove.

What if you add too much water?

Overshooting is easy to do and not a disaster. If the gauge reads well above 1.5 bar on a cold system, bleed a radiator a little at a time until it drops back into range. Worcester Bosch’s system filling guide recommends the same thing: release a bit of water through a radiator bleed valve and keep an eye on the gauge as you go.

Don’t leave it high. Every sealed system has a pressure relief valve that opens if pressure climbs too far, sending water out through a small pipe on an outside wall. That valve is a safety device, not a pressure control, and regularly forcing it open can stop it sealing properly afterwards.

Why the filling loop has to come off afterwards

Taking the hose off isn’t just tidiness. The water in your heating circuit has been sitting in pipes and radiators for years and often contains inhibitor chemicals, so it mustn’t be able to flow back into the drinking water supply. Under the Water Supply (Water Fittings) Regulations, a temporary filling loop should be disconnected and stored once the system is topped up, with the valves closed.

Built-in keyless links are different, because they’re designed with a backflow prevention device and are approved to stay connected. If you’ve got an external hose that’s been left on permanently, mention it at your next service.

When repressurising isn’t the real fix

Topping up after you’ve bled the radiators, or once in a blue moon, is normal. Bleeding radiators can cause the pressure to drop, so a top up afterwards is expected. What isn’t normal is having to repressurise every few days or weeks. That means water is escaping from somewhere, and adding more just hides the problem while the cause gets worse.

Stop topping up and get the boiler looked at if:

We’ve covered the usual culprits in more detail in our guide to why your boiler loses pressure and when to be concerned. For other common faults, our boiler repairs troubleshooting FAQs are a good next stop.

What you should never do

Repressurising only involves the filling valves, key or lever on the outside of the boiler. Never take the casing off or try to adjust anything inside. The HSE is clear that anyone working on gas appliances in your home must be a Gas Safe registered engineer, and there’s good reason for that. The inside of a boiler involves gas, combustion and flue components that can cause carbon monoxide or gas leaks if disturbed. Our gas boiler safety tips cover the warning signs every household should know.

Pressure keeps dropping? Book a Gas Safe engineer

If your boiler won’t hold pressure, or you’d simply rather someone else did it, our Gas Safe registered engineers cover Bognor Regis, Chichester, Littlehampton, Selsey, Pagham and the surrounding villages. We’ll find the leak or faulty part and fix it properly, so you’re not topping up all winter. Find out more about our boiler repairs, or get in touch to book a visit.

An annual boiler service is also the best way to catch weeping valves, tired seals and a flat expansion vessel before they leave you with a cold house in January.

FAQs

Is it safe to repressurise a boiler yourself?

Yes, as long as you only use the filling loop, key or lever on the outside of the boiler and follow your manual. It’s designed to be done by homeowners. Never remove the boiler casing, as any work inside a gas boiler must be carried out by a Gas Safe registered engineer.

How long does it take to repressurise a boiler?

Usually around five minutes, plus however long the system takes to cool if the heating has been on. The water itself flows in within seconds, so most of the time is spent finding the filling loop and watching the gauge.

Should I turn the boiler off before repressurising it?

Yes. Switching it off and letting the system cool gives you an accurate pressure reading, because hot water expands and pushes the gauge up. Topping up a hot system can leave the pressure too high once it cools and reheats.

Why does my boiler keep losing pressure after I repressurise it?

Pressure that drops again within days or weeks almost always means water is escaping, either through a leak in the pipework, radiators or boiler, or through a faulty pressure relief valve. Keep topping up and you mask the fault rather than fixing it. Book a Gas Safe engineer to trace the cause.

How do I repressurise a combi boiler without a filling loop?

Many combi boilers, particularly Worcester Bosch models, use a built-in filling key or a blue keyless lever instead of a hose. Check underneath the boiler and in the manual. If you can’t find any way of filling the system, call an engineer rather than improvising.